Ventilation Controls for Dairy
From simple manual switches to thermostat controlled and fully automatic touchscreen interface, you can trust AutoVent to keep your livestock as comfortable as you are.
Ventilation Controls For Livestock
Environmental controllers are essential for dairy and livestock. Ventilation dramatically impacts the health and production of the animals. Proper temperature, humidity, and ventilation are critical to the comfort and health of the animals.
The Smart Series

KVT-400
Take the guesswork out of ventilation with a high-definition touchscreen interface that manages your curtains based on real-time wind speed, direction, and temperature. It’s like having a dedicated manager for your barn’s climate, 24/7.

Captain
The Captain balances curtain and fan performance using integrated wind and temperature sensors. By automating these movements, you reduce energy waste and ensure a consistent environment that keeps your herd productive even as the weather shifts.
The Essentials

FanChief
Stop manually toggling switches. The FanChief monitors barn conditions to run your fans only when necessary, extending the life of your equipment and significantly lowering your monthly utility costs.

Serf C90
Designed specifically for compatibility with 90-volt curtain motors, the SERF C90 offers an easy-to-use interface for farmers who need dependable automation without unnecessary complexity.

Agriculture Duty VFD
Bring variable speed capabilities to any 3-phase project. This heavy-duty VFD allows you to ramp motor speeds up or down smoothly, preventing harsh starts and allowing for precise air-flow adjustments.
Manual & Hardware

Manual Controls
Our 24-volt manual curtain motor controls provide a rugged, reliable backup. Featuring heavy-duty toggle switches, these units are perfect for barns requiring direct operator control or emergency overrides.

Curtain Motors
Powerful, durable, and built for the barn environment. Our automated curtain motors provide the consistent torque needed to move large curtain systems smoothly, year after year.
Good to know
Proper environmental control is also essential for production. Heat stress in cows reduces milk production and lowers milk component levels. Similarly, poor ventilation can lead to respiratory problems in calves, which can make preventable lifetime performance losses.
Specifications
| Models | Captain6 | Captain6 | Captain10 | Captain10 | KVT-400 | KVT-400 |
|---|---|---|---|---|---|---|
| Part number | CP60E | CP60E-PS | CP100 | CP100-PS | KVT-400 | KVT-400PS |
| Relay outputs | 6 | 6 | 10 | 10 | 10 | 10 |
| Variable speed outputs | 1 | 1 | 1 | 1 | 1 | 1 |
| 24vdc output *1 | NA | 10 amp | NA | 20 amp | NA | 20 amp |
| Expansions | ||||||
| KVT-EX802 compatible | No | No | No | No | Yes | Yes |
| KVT-EX1602 compatible | No | No | No | No | Yes | Yes |
| KVT-EX02 compatible*2 | Yes | Yes | Yes | Yes | Yes | Yes |
| Sensors | ||||||
| Temperature sensor | Yes | Yes | Yes | Yes | Yes | Yes |
| 2nd temp sensor | Option | Option | Option | Option | Option | Option |
| Wind speed | Option | Option | Option | Option | Yes | Yes |
| Wind direction | No | No | No | No | Yes | Yes |
| Rain sensor | Option | Option | Option | Option | Yes | Yes |
| Equipment | ||||||
| Max curtains | 3 | 3 | 5 | 5 | 15 | 15 |
| Max fans | 6 | 6 | 10 | 10 | 10 | 10 |
| Max soakers | 6 | 6 | 10 | 10 | 10 | 10 |
| Internet gateway | Yes | Yes | Yes | Yes | Yes | Yes |
| Models | KVT-Expansion | KVT-Expansion | KVT-Expansion |
|---|---|---|---|
| Part number | KVT-EX802 | KVT-EX1602 | KVTEX02 |
| Relay outputs | 8 | 16 | 0 |
| Variable speed outputs | 2 | 2 | 2 |
| Part number | Motors | Max Amps | Override Toggles | Interface | Fuse Sizes | Enclosure Size |
|---|---|---|---|---|---|---|
| CMR-0224 | 1 | 10 | Yes | dry contact | 5,7.5,10 | 7x11x6 |
| CMR-3224 | 2 | 10 | Yes | dry contact | 5,7.5,10 | 7x11x6 |
| CMR-3224-5 | 2 | 20 | Yes | dry contact | 5,7.5,10 | 7x11x6 |
| CMR-0424-5 | 4 | 20 | Yes | dry contact | 5,7.5,10 | 11x15x6 |
| CRR-0224 | 1 | 10 | No | dry contact | 5,7.5,10 | 7x11x6 |
| CMC-0100 | 1 | 10 | Yes | none | 5,7.5,10 | 7x11x6 |
| CMC-0400-5 | 4 | 20 | Yes | none | 5,7.5,10 | 7x11x6 |